Difference between revisions of "Template:Chembox/doc/sandbox"
< Template:Chembox | doc
Jump to navigation
Jump to search
imported>DePiep |
imported>DePiep |
||
| Line 130: | Line 130: | ||
<table><tr><td> | <table><tr><td> | ||
<pre style="color:darkred"> | <pre style="color:darkred"> | ||
| − | |||
| − | |||
| − | |||
| Autognition | | Autognition | ||
| AutognitionC | | AutognitionC | ||
| Line 140: | Line 137: | ||
</td><td> | </td><td> | ||
<pre> | <pre> | ||
| − | |||
| − | |||
| − | |||
-> Use AutoignitionPt= for todo | -> Use AutoignitionPt= for todo | ||
-> Use AutoignitionPtC= for the lower range value; range will show when _CH= is used | -> Use AutoignitionPtC= for the lower range value; range will show when _CH= is used | ||
Revision as of 14:52, 17 February 2014
Advanced
|SectionX = {{Chembox Properties
| MeltingPtPrefix =
| MeltingPtC =
| MeltingPtF =
| MeltingPtK =
| MeltingPtCH =
| MeltingPtFH =
| MeltingPtKH =
| MeltingPt =
| Melting_ref =
| Melting_notes =
| BoilingPtPrefix =
| BoilingPtC =
| BoilingPtF =
| BoilingPtK =
| BoilingPtCH =
| BoilingPtFH =
| BoilingPtKH =
| BoilingPt =
| Boiling_ref =
| Boiling_notes =
}}
| SectionX = {{Chembox Hazards
| FlashPtPrefix =
| FlashPtC =
| FlashPtF =
| FlashPtK =
| FlashPtCH =
| FlashPtFH =
| FlashPtKH =
| FlashPt =
| Flash_ref =
| Flash_notes =
| AutoignitionPtPrefix =
| AutoignitionPtC =
| AutoignitionPtF =
| AutoignitionPtK =
| AutoignitionPtCH =
| AutoignitionPtFH =
| AutoignitionPtKH =
| AutoignitionPt =
| Autoignition_ref =
| Autoignition_notes =
}}
|
* Melting point, prefix for numbers (NEW) * Melting point in C, numeric value * Melting point in F * Melting point in K * Melting point in C (high of range) * Melting point in F (high of range) * Melting point in K (high of range) * Plaintext instead of any numerics * Reference (NEW) * Postfix, any plaintext; not bracketed * Boiling point, prefix for numbers (NEW) * Boiling point in C * Boiling point in F * Boiling point in K * Boiling point in C (high of range) * Boiling point in F (high of range) * Boiling point in K (high of range) * Plaintext instead of any numerics * Reference (NEW) * Postfix, any plaintext; not bracketed -- Parameter list expanded, matching list above * Flash point, prefix for numbers * Flash point in C, numeric value * Flash point in F * Flash point in K * Flash point in C (high of range) * Flash point in F (high of range) * Flash point in K (high of range) * Plaintext instead of any numerics * Reference * Postfix, any plaintext; not bracketed * Autoignition point, prefix for numbers * Autoignition point in C * Autoignition point in F * Autoignition point in K * Autoignition point in C (high of range) * Autoignition point in F (high of range) * Autoignition point in K (high of range) * Plaintext instead of any numerics * Reference * Postfix, any plaintext; not bracketed |
Deprecated
From live: Template:Chembox Properties/doc The next parameters are deprecated:
| MeltingPtCL | MeltingPtFL | MeltingPtKL | BoilingPtCL | BoilingPtFL | BoilingPtKL |
-> Use MeltingPtC= for the lower range value; range will show when _CH= is used -> Use MeltingPtF= for the lower range value; range will show when _FH= is used -> Use MeltingPtK= for the lower range value; range will show when _KH= is used -> Use BoilingPtC= for the lower range value; range will show when _CH= is used -> Use BoilingPtF= for the lower range value; range will show when _FH= is used -> Use BoilingPtK= for the lower range value; range will show when _KH= is used |
Deprecated as of December, 2013 Adding Hazards:
| Autognition | AutognitionC | AutognitionF | AutognitionK |
-> Use AutoignitionPt= for todo -> Use AutoignitionPtC= for the lower range value; range will show when _CH= is used -> Use AutoignitionPtF= for the lower range value; range will show when _FH= is used -> Use AutoignitionPtK= for the lower range value; range will show when _KH= is used |